Mixed bed refers to a system where water successively flows through a cation bed filled with hydrogenous cation exchange resin and anion bed filled with hydrogen and oxygen anion exchange resin. The hydrogenous cation exchange bed is used to remove cation in water; the hydrogen and oxygen anion exchange bed is used to remove anion in water. The compound bed can basically remove mineral salts in water. In order to obtain better salt removal effects, the cation bed contains strong-acid cation exchange resin, and the anion bed contains strong-base anion exchange resin.
| Type | Water output | Diameter of the water inlet | Quality of the water output | Dimension | Weight (kg) | ||||
|---|---|---|---|---|---|---|---|---|---|
| T/H | GPD | MΩ.CM | L | W | H | Net | Gross | ||
| MB-2 | 2 | 12700 | 1' | > 10 | 1.6 | 0.8 | 2 | 150 | 130 |
| MB-5 | 5 | 31700 | 1' | > 10 | 1.85 | 1 | 2 | 180 | 230 |
| MB-10 | 10 | 63400 | 1 - 1/2' | > 10 | 2 | 1 | 2.3 | 205 | 350 |
| Type | MB-2 | MB-5 | MB-10 |
|---|---|---|---|
| DI tub | 1465 / 1665 | 1665 / 2162 | 2472 |
| Low pressure gauge | 0 - 1.0 Mpa | 0 - 1.0 Mpa | 0 - 1.0 Mpa |
| Flow meter | 1 - 17 GPM | 1 - 17 GPM | 5 - 100 GPM |
| Pneumatic valve | 1 / 2" , 1' | 1 / 2" , 1" , 1- 1 / 2'" | 1 / 2" , 1" , 1- 1 / 2'" |
| Ejector | 1 / 2" | 1 / 2" | 1 / 2" |
| Resistivity meter | 0 - 20MΩ.CM | 0 - 20MΩ.CM | 0 - 20MΩ.CM |
| Electronic control | PLC controller | PLC controller | PLC controller |